Descripción

SPECIFICATIONS

Brand Name: TONGOU

Breaking capacity: 6KA

Certification: CE,CE CB TUV

Does it include a Battery?: No

Does it include wireless functionality?: No

EU LVD Voltage: High voltage: Above 50Vac or 75Vdc

Electro-mechanical endurance: More than 20000 cycles

High-concerned chemical: None

Model: 30 - 300mA is Magnetic type, 10mA is Electronic type

Model Number: RD4-63

Origin: Mainland China

Rated current: 16A

Rated frequency: 50/60Hz

Rated making and breaking capacity: 630A

Rated residual operating current: 10 mA

Rated voltage: 230V AC, ( 110V Customized )

Residual Current characteristic: AC

Standard: IEC/EN 61008-1

Type: Earth Leakage

is_customized: Yes











  • Hot Sale

General:

Please note

this is an RCCB (Residual Current Circuit Breaker) which provides leakage protection only. It does not include short-circuit protection. For complete protection including both leakage and short-circuit protection, please select our RCBO model (TOBD6)


Tips: 30mA, 100mA, 300mA is electromagnetic type, 10mA is electronic type.10mA cannot be tested with 5V battery.

There is a wiring diagram above the test button, please follow the it. The power supply must enter from the top and output from the bottom. The neutral line on the left and the live line on the right.


The default rated voltage of the product is 230V, (110V needs to be customized, please contact customer service)

Residual Current Circuit Breaker is applicable to electric circuits with rated voltage 230/400V AC, frequency 50/60Hz and rated current up to 16Amp.

The RCCB provides indirect protection to the operator’s body under such condition that the exposed live parts should be connected to a proper earthing pole.The RCCB also provides protection against the fire danger caused by earth fault current due to function failure of over-current protection device.


Special tips:

1. RCCB with rated sensitivity up to 10mA could be used as supplementary protecting device in case other
protecting device fails its protection against electric shock.
2. RCCB designed for household installation and other similar application, is for non-professional operation,
and no maintenance is required.
3. RCCB provides on protection against electric shock resulted from direct contacts of both protected lines,or
leakage current between these two lines.
4. Particular devices such as surge protective devices,surge arrester etc are recommended to install at upstream line to RCCB as precaution against potential surge voltage and current occurring at its power input side.

5. Satisfying conditions and applications as mentioned above,RCCB with “ON-OFF” indicating device is considered suitable for isolation function.





Model Name

TORD4-63

Model

Electronic / Magnetic type

Residual Current characteristic:

AC

Pole No:

2P

Rated making and breaking capacity

630A

Rated current(A)

16A

Rated voltage

110V 220V 230V AC

Rated frequency

50/60Hz

Rated residual operating current |△(A):

0.01

Rated residual non operating current |△ no:

0.5|△ n

Rated conditional short-circuit current inc:

6kA

Rated conditional residual short-circuit current |△c:

6kA

Tripping duration:

Instantaneous tripping ≤0.1s

Residual tripping current range:

0.5||△n~|△n

Electro-mechanical endurance

≥20000 cycles

Connection capacity:

Rigid conductor 25mm⊃2;

Connection terminal

Screw terminal
Pillar terminal with clamp

Fastening torque

2.0 Nm

Installation

On symmetrical DIN rail 35mm
Panel mounting

  • About Us


Dear TONGOU Buyer:


"Thank you for your attention to and for placing an order in our store."


1.If the amount of your order is greater than $150 (the selling price does not include VAT).

In any case, you pay the same amount of money. If next time you don't want to pay VAT locally, please make sure your order amount is less than $150, and will charge VAT automatically.



2.The item price is not including any taxes or charges locally, if the parcel get stuck at local customs, buyer need to contact the customs and do the customs clearance. We won't bear the customs taxes or any fees caused by custom or buyer reject package .


3. If you choose DHL,this is not including DHL remote cost/custom duty, or any commission charged by DHL for custom clearance or warehouse storage cost.


4.Please open the parcel in post officer's presence,If the parcel damaged or empty(stolen),please ask the post office to provide official document,especially the claim request paper.


5.Five-Star Feedback is very important for us. We have one year warranty. We hope that you can contact us immediately before you give us neutral or negative feedback, so that we can help you solve the problem.Thanks!